LEDpavers.com Solar LED Paver, LED Landscape Lighting, LED Pathway Lighting: Architectural and Landscape design using solar LED lights, pavers and renewable technologies Your Premier Destination For Solar LED Paver Accent Lighting And All Things Solar!
Email Icon contact@LEDpavers.com
Phone Icon Call us at 310 929 7449
My Account | Cart 
Home  |  About Us  |  Gallery  |  FAQ  |  Contact Us
Products

    arrow Solar Cynergy Pavers

    arrow Solar LED Tiles

    arrow Solar LED Pavers

    arrow Solar Light Works

    arrow Transportation Series

    arrow Solar Power

        arrow Batteries

        arrow Cables & Wires

        arrow Charge Controllers

        arrow Electrical Distribution

        arrow Inverters

        arrow Meters & Analysis

            arrow Amp & Volt Meters

            arrow Battery Monitors

            arrow Cables For Monitors

            arrow Killowatt & Induction

            arrow Shunts

            arrow Solar Site Analysis

        arrow Power Systems

        arrow Solar Cells

        arrow Solar Panels

        arrow Trackers & Mounts

    arrow Wind Energy

Chat Online
Information

    arrow Shipping & Returns

    arrow Privacy Notice

    arrow Conditions of Use

    arrow Contact Us


Merchant Services
Bogart Engineering 500A, 50Mv Shunt $35.00


Bogart Engineering
TRI-METRIC SHUNTS
500A/50MV

Specifications

  • Resistance: "500 Amp at 50 millivolts", or 0.1 milliohm.
  • Max. steady state current, amps: 410 Amperes
  • Thermal time constant: 18 minutes
  • Overload current: If normally operated at less than 300 amps, it will take overloads to 500 amps for durations of less than 5 minutes.
  • Physical characteristics: Has a plastic base 3.25 x 1.75 in. with two mounting holes .205 "dia, 1.25" apart o.c. 1.75 inches overall height. High current connections are made to two bolts (3/8"-16) which are 1.50 in. apart (o.c).

How a shunt works

A shunt is necessary in order to measure amps and amp-hours with the TriMetric battery monitor. A shunt is an accurate, very low resistance resistor which is placed "in line" with the wire carrying the current to be measured. With the TriMetric, it is usually placed in the negative wire from the battery bank, such that all the current going into the battery (charging) or out (discharging) must pass through it. Connected in this way it will be set up to monitor "net" amp-hours in and out of the battery. (It also could be placed in series with the negative wire coming from a solar array--or other charging source--in which case it would measure only the solar array current, if that were desired--to show total solar "amp hours" production.) The shunt needs to be placed near the batteries; since these wires carry very high currents the wires from the batteries must be kept short to minimize electrical losses.

Shunt resistance

When current flows through the shunt, a small voltage is developed across the shunt which is proportional to the current flow. The TriMetric battery monitor accurately measures this very low voltage and converts it to the "amps" reading on the meter. The resistance, which is the ratio between the voltage across the shunt and the current flowing through it, is a constant for any particular shunt--and is one of its important parameters. For most substances, resistance is usually described in "ohms", however for some reason shunts are described by the voltage drop that occurs with a certain current: for example: "50 millivolts at 500 amperes." However the meter only cares about the ratio-which is the resistance--so a 500Amp/50 millivolt shunt is equivalent, from the TriMetric's view, to a 250Amp/25 millivolt shunt. They both have a resistance of 0.1 milliohm, or one ten thousandth of an ohm.

Shunt Cable ConnectionSetting up the TriMetric for correct shunt

The TriMetric is designed to use either a 500 Amp/50 millivolt (0.1 milliohm) or 100 Amp/100 millivolt (1.0 milliohm) shunt. The latter shunt delivers 10 times the voltage for a given current flow through the shunt, so the meter can show an extra digit of current resolution (down to 0.01 amp) compared with the 500 Amp/50 millivolt shunt, which displays a minimum current of 0.1 amp. To make the TriMetric read "amps" and "amp-hours" correctly, you must tell the TriMetric which shunt is being used. This is done by programming either an "L" (low) or "H" (high) in one of the program modes. ("L" for the 100A/100 mV shunt, and "H" for the 500 A/50 mV shunt.) For how to do this refer to TriMetric instructions under "How to set efficiency factor and shunt type".

Source: Bogart Engineering

 

 

 